flex armor thermocouple sensor
Flex Armor RTDs- Flex armor resistance temperature detectors (RTDs), Thermistor, Semi-Conductor and Thermocouple temperature sensors are available in 3 configurations:
They are available in:
Flex Armor Sensor
Flex Armor Sensor with transition
Flex Armor Sensor with 2 transitions
Flex armor temperature sensors are commonly used in extruder and plastic processing and bearing industries. The samples shown are 100 ohm RTD temperature sensors in a 4-wire, teflon insulated configuration. This provides an operating temperature ran of -50 to 250 C. Fiberglass insulated wire is also an option.
The length of the tip, sheath, transition and lead wire are specified by the customer to suit the application. The lead wire can be supplied as bare wire, terminated with plugs, jacks, spade lugs or junction boxes. For long cable runs, stainless steel overbraid or flex armor can be added to protect the lead wires. These temperature sensors configurations can be manufactured as RTDs, Thermistors, and Thermocouples.
Common types include: 100, 500, and 1000 ohm RTD temperature sensors.
Thermistors temperature sensors: 2K, 3K, 4K, 5K, 10K, 30K, 50K, 100K
Types of Thermocouples: T, J, E, K, N, R, S, B
Specifications:
Platinum 100 ohm, .00385 Alpha
Temperature Range -50 °C to 400 °C
DIN Class B +/- .12% Ohms at 0 °C
Celsius= .3 Ohms + (0.005 ohms x (temperature))
sales@thermometricscorp.com